Description |
|
The BIOFORCEN Biomechanics Force Plate model JP4060 was specifically designed for the precise measurement of ground reaction forces. The plate measures the three orthogonal force components along the X, Y, and Z axes, and the moments about the three axes, producing a total of six outputs. The high sensitivity, low crosstalk, excellent repeatability and long term stability of this plate makes it ideal for research and clinical studies. The JP4060 is easy to use and is available in 5,000 Newton vertical capacity.
|
Application |
|
The JP4060 model Biomechanics Force Plate can be used for biomechanics, engineering, medical research, orthopedics, rehabilitation evaluation, prosthetics, and general industrial uses. Specific uses include gait analysis, “Romberg” testing or stability analysis, neurological analysis, prosthetics fitting, athletic performance, shoe design, and force, power, and work studies. | |
|
Model
|
Range Fz(KN)
|
L/W (mm) |
Uses
|
| JP4040 |
0.2 - 1 - 5 - 10 |
400 × 400 |
Joints, balance |
| JP4060 |
1 - 5 - 10 - 20 |
400 × 600 |
Gait, teaching |
| JP5050 |
1 - 5 - 10 - 20 |
500 × 500 |
Gait, balance |
| JP6060 |
10 - 20 |
600 × 600 |
Sports, Teaching |
| JP5080 |
5 - 10 - 20 |
500 × 800 |
Shooting, gymnastics |
| JP40100 |
5 - 10 - 20 |
400 × 1000 |
Gait |
|
JP60100 |
5 - 10 - 20 |
600 × 1000 |
Hurdle |
| JP8090 |
5 - 10 - 20 |
800 × 900 |
Vibration |
| JP80160 |
10 - 20 - 40 |
800 × 1600 |
Weightlifting |
| JP40200 |
5 - 10 - 20 |
450 × 2000 |
Gait cycle |
|
Notes |
Features
|
Uses
|
|
LW |
Light weight, rugged, portable |
Light weight, rugged, portable, light weight, the weight of distance measure parameters such as joint |
|
CC |
Cirsle Style |
Round for special occasions, such as shooting, balancing, etc. |
|
NJ |
One-dimensional edge detection, high accuracy |
vertical jump force, jump height, and movement evaluation |
|
WP |
Waterproof structure |
suitable for outdoor / water projects, etc. |
|
MR |
External signal processor |
gait analysis, balance test, mechanical analysis |
|
NC |
Non-conductive force plates |
prevent signal interference for special occasions |
|
SE |
Balance testing |
static balance |
|
CAN |
CAN Bus multiple GC (15 units) |
long jump, sprint and other track and field |
|
|
Product Performance:
Patented structure, stainless steel / aluminum surface, beautiful appearance, automatic leveling, a variety of installation, simple and reliable;
Can detect forces in three directions of space and moment, two force plates both synchronous acquisition can also be used alone, could be combined computing power of the human body, torque, pressure center center of pressure, friction coefficient, angle of attack, acceleration , speed of more than 20 items of kinetic parameters;
USB data interface, the hardware can sync signal input and output;
Powerful software: Chinese, English software version; graphical interface, real-time detection of Fx / Fy / Fy / Mx / My / Mz, real-time display COP point (center of pressure) of the trajectory, supporting data auto-zero; sub-screen display, curve can be partially amplification;
Feature extraction and reporting function: the peak power can be extracted, the regional location tracing foot walk cycle phase; drawing parametric curves and can save the data, and can print out standard data reporting and analysis;
Open data output format, are available on request processing software development and export-processing software and application software to establish a shared database or between the dynamic link library; and to achieve the synchronization;
System can be synchronized trigger signal for the camera to capture the use of scientific research to support kinematics; software can display video files, so that application of scientific research and teaching demonstration.
|
 |
|
BIOFORCEN’S BIOFORCEN SYSTEMS Systems are complete gait and balance analysis force plate systems. Each system consists of force plate, amplifiers, cables, mounting hardware, A/D converter, and BIOFORCEN-Analysis analysis software, all sold at a special system price.
CUSTOM BIOFORCEN also offers special multi-axis transducers to meet your specific needs. Units are available in waterproof versions and various sizes, load capacities, sensitivities, and materials. Units 1 inch (1.7 cm) in diameter, and plates with capacities as high as 20,000 Newtons have been made. Contact BIOFORCEN for any custom requirements. |
|
SERIES SPECIFICATIONS Fx, Fy Capacity (N): 2.5 KN Fz Capacity (N): 5 KN Mx Capacity (Nm): 1 KNm My Capacity (Nm): 1.5 KNm Mz Capacity (Nm): 0.75 KNm Fx, Fy Sensitivity (μV/[V*N]): 0.30 Fz Sensitivity (μV/[V*N]): 0.12 Mx, My Sensitivity (μV/[V*Nm]): 0.25 Mz Sensitivity (μV/[V*Nm]): 0.37 |
 |
|
GENERAL SPECIFICATIONS Safe Temperature Range: 0~50OC Compensated humidity Range: 20~70%RH Safe Excitation Voltage: 12V DC Weight: 35 Kg Crosstalk: Less than 2% on all channels Sensitivity Change with Temperature:≤1%/°C Fx, Fy, Fz hysteresis: ≤ 1% Full Scale Output Fx, Fy, Fz non-linearity: ≤ 1%% Full Scale Output
|
|